Demonstrations / Controls engineering

Pump station simulation

Explore communications loss, sensor faults and controlled recovery. Run the sandbox or work through four guided decisions.

Read the water utility architecture article →

Interactive teaching model / PS-01

Drop the link. Watch what changes.

Try: press Play → disconnect WAN → increase demand → try a supervisory command → restore WAN → confirm checks → approve recovery.

Illustrative software model only. Values are dimensionless (0–100), steps are not seconds, and the local response is deliberately simplified. A real plant needs engineered timeouts, interlocks and loss-of-link logic. This is not a hydraulic simulator, PLC emulator or evidence that T06 passed. Power and RTU hardware remain healthy in this example. PT-01 failure is now an explicit bad-quality scenario; undetected drift or spoofed valid data are not simulated. Communications loss is detected immediately here.

· Model step ·

At PS-01 · model truth

Local control continues

At PS-01 · model truth: pump, storage tank and outletSimplified process drawing. Read level and flow values below.Supply →P-01 pumpIllustrative tank60% full→ Users
Tank 60%In 5.0Out 5.0

At SCADA · received picture

Fresh telemetry

At SCADA · received picture: pump, storage tank and outletSimplified process drawing. Read level and flow values below.Supply →P-01 pumpIllustrative tank60% full→ Users
Tank 60%In 5.0Out 5.0

Tank level is a separate illustrative storage variable, not the pressure reading below. In/out values are model units per step. Play advances two model steps per second; Pause freezes the teaching model. Advance one step remains available when paused. This playback speed is not a real plant timescale. At 0% or 100% the model is clipped, not physically validated. Real pump curves, tank hydraulics and protective controls are outside this example.

At the station

model units

Local automatic feedback control active. Target: . Demand: .

At central SCADA

model units

Last received sample freezes during WAN loss. It is not current plant state.

Authority & alarms

Paused · use Play or advance one step

Target change toggles 50 ↔ 60 only when authority is enabled. Rejected commands are discarded, never queued. Restoring the link restores telemetry, not supervisory authority. Confirming checks is an educational interaction, not real equipment verification. No external connections or saved results.

Operator response · communications versus measurement

Teaching fallback: PT-01 bad quality suspends feedback and holds the last modeled pump output until repair, checks and approval. The process can still change under demand. This arbitrary demonstration is not a safe state or an instruction to hold a real pump. Actual fallback, escalation limits and stop conditions require a site hazard review and approved procedure.

Tank and flow drawings show teaching-model truth, with separate illustrative telemetry. PT-01 measures pressure, not tank level; a pressure sensor fault does not freeze unrelated telemetry. No independent physical sensors or real protection are implemented here.

Event journal · most recent first

    Learn by deciding / 5–10 minutes

    What should the operator do?

    Four guided scenarios compare communications loss, sensor failure, both faults and recovery. Each loads a paused state into the model above. Manual simulation controls are locked during the exercise so the question matches the state. Starting or restarting replaces your sandbox state. Answers are held in memory for your end-of-exercise review; nothing is saved persistently or sent.

    Use approved site procedures and responsible operations/engineering authority in real facilities. No generic answer here authorizes a physical change or establishes a safe operating state.

    Teaching boundary

    This dimensionless model illustrates failure and recovery concepts. It does not validate a water utility architecture or any plant acceptance test. No live utility is represented. See the companion article for the design, sources and unexecuted acceptance plans.